The mobile fuel cell system C380

Headerbild spezifications

Output power1

380 W

Nominal voltage           

12 V or 24 V

Nominal charge current @ 12 V DC / 24 V DC

31.5 A / 15.75 A

Max. charge current @ 12 V DC / 24 V DC

36 A / 18 A

Charging capacity

9 kWh  / day

Charging capacity @ 12 V DC / 24 V DC

760 Ah per day / 380 Ah per day

Min. operating voltage

10.5 V DC or 21 V DC

Max. operating voltage

15 V DC or 30 V DC

Start voltage in automatic mode4

12.2 V DC / 24.4 V DC (factory setting; adjustable between 11.5 V DC and 13 V DC / 23 V DC)

Recommended battery types

Lead acid, lead gel, AGM (additional battery types possible – please consult EPH elektronik)

Adjustable charging end voltage2

13.5 V DC to 15 V DC or 27 V DC to 30 V DC

Gas type

Hydrogen 5.0 (99.999% purity)

Required hydrogen operating pressure

1 to 6 bar

Hydrogen consumption in nominal operation

4.9 Nl/min

Dimensions L x W x H

433 x 440 x 175 mm, 19" insert (4 U)

Weight

10.6 kg

Operating temperature

+ 0.5 °C to + 40 °C

Operation and settings

via operating unit on the device

Interface

RS485

 

Gas supply

Linde Genie®   

Steel gas cylinder

Gas type

Hydrogen 5.0 (99.999% purity)

Hydrogen 5.0 (99.999% purity)

Volume

20 l

50 l

Fill capacity

approx. 5 m3

approx. 12,5 m3

Fill pressure

approx. 300 bar

approx. 300 bar

Energy content

ca. 6,5 kWhel

ca. 16,2 kWhel

Charging capacity @ 12 V DC / 24 V DC

approx. 540 Ah / 270 Ah

approx. 1350 Ah / 675 Ah

Operating time at max. output power

approx. 17 h

approx. 43 h

External diameter

approx. 330 mm

approx. 230 mm

Total length

approx. 865 mm

approx. 1700 mm

Total weight

approx. 32.7 kg

approx. 80 kg

Gas cylinder connection3

as per DIN 477 no. 57

as per DIN 477 no. 57

 

1 Reduces as the operating time and start/stop procedures increase.
2The DONATOR® fuel cell system charges at an approximately constant power until the set charging end voltage is reached. After the charging end voltage is reached, the output current and output power are reduced. The system shuts down when the device's internal switch-off condition is met.
3Cylinder pressure 300 bar
412.2 V DC or 24.4 V DC (factory setting, can be adjusted between 11.5 V DC and 13 V DC and 26 V DC)

How to find us

EPH

EPH elektronik
Produktions- und
Handelsgesellschaft mbH

Rudolf-Diesel-Straße 18
D-74354 Besigheim-Ottmarsheim

 

Phone +49 (0) 7143 8152 0
Fax +49 (0) 7143 8152 900
info@eph-elektronik.de